Application Principles
To cool air in a compact and confined area!

1.
Direct Cooling with Conductive Connection

2.
Indirect Cooling with Heat Exchanger+Fan

3.
Direct Cooling with Thermosyphon

4.
Direct Cooling with Brine/Glycol/Nitrogen
- 1Cooling performance-Least:Aluminum plate is not uniformly and the thermal resistance between the aluminum plate and inside air is relatively large. Limited effective volume.Influence of frost on cooling-Little:The surface area of the aluminum plate exposed to the inside air doesn't become smaller when aluminum plate surface is covered with frost.Others:The vibration of the FPSC is conducted to the insulated container and aluminum plate directly and they can become a source of noise.2Cooling performance-Best:The thermal resistance between cold side of FPSC and heat exchanger is relatively small. The thermal resistance inside air is relatively small too.Influence of frost on cooling-Large:When the space is filled with frost, air can't flow there. The surface area of finned plate exposed to the inside air becaomes smaller and cooling performance is reduced.Others:1. It is necessary to specify a fan motor suitable for operation at desired qorking temperature.2. The heat from the fan motor adds an additional heat load and reduces the overall cooling performance.3Cooling performance-Better:Aluminum plate is cooled more uniformly than "1". Two-phase heat transport allows for the lowest thermal resistance between the aluminum plate and FPSC.Influence of frost on cooling-Little:The surface area of the aluminum plate exposed to the inside air doesn't become smaller when aluminum plate surface is covered with frost.Others:
1. It is necessary to define and prepare a suitable working fluid for desired operating temperature.2. It is necessary to prepare charging equipment for working fluid.4Cooling performance-Better:Copper tube is attached on aluminum plate with more freedom than "3". Plate is cooled more uniformly than "3" but results in a higher thermal resistance.Influence of frost on cooling-Little:The surface area of the aluminum plate exposed to the inside air doesn't become smaller when aluminum plate surface is covered with frost.Others:
1. It is necessary to prepare suitable brine and pump for desired operating or storage temperature.2. The heat from the pump motor adds an additional heat load and reduces the overall cooling performance.3. It is necessary to take precautions against potential brine leakage. Product Models
Stirling Cooler, which we refer to as the FPSC (Free Piston Stirling Cooler). RIGID has prepared a product lineup of Stirling Coolers that can cool air temp to 30℃ ~ -160℃ using helium gas as the refrigerant. The Stirling Cooler, which differs from a compressor, is a cooling system that continuously repeats gas compression and adiabatic expansion and uses naturally occurring helium gas as the refrigerant.
Helium is a very safe gas that is entirely harmless to our global environment. The typical use of our Stirling Cooler is in portable freezers, and refrigerators, but we are also developing a product lineup for use in laboratory equipment and in medical devices used for low-temperature distribution of goods.
Capacity: 40W
Input Power: 12V
N.W: 2.2kg (4.8lbs)Coolant: Helium=2.5g
Size: ODФ86mm x Length260mm
Working Lifetime: Continuously operation ≥10,000hrs
Working Condition: 0℃~+60℃(32℉~140℉)
Installation: Any direction is workableTemperature Sensor of Controller: -1℃ to -99℃
Temp Range in Cold Fin (Cold part): -100℃~ 0℃
Capacity: 80W
Input Power: 24V
N.W: 2.2kg (4.8lbs)Coolant: Helium=3.0 g
Size: ODФ86mm x Length270mm
Working Lifetime: Continuously operation ≥10,000hrs
Working Condition: 0℃~+60℃ (32℉~140℉)Installation: Any direction is workable
Temperature Sensor of Controller: -1℃ to -99℃
Temp Range in Cold Fin (Cold part): -140℃~ 0℃Capacity: 100W
N.W: 4.0kg (8.8lbs)
Coolant: Helium=3.0g
12V~30V DC Power Supply
External Size: 132mm×132mmx336mm (LxWxH)
Working Lifetime: Continuously operation ≥10,000hrs
Working Condition: 0℃~+60℃ (32℉~140℉)
Installation: Any direction is workable
Temperature Sensor of Controller: 0℃ to -140℃
Temp Range in Cold Fin (Cold part): -160℃ ~0℃Cooling Performance Curve
Using safe and environmentally friendly Helium gas as the refrigerant. With the international advanced Free-piston Stirling technology, RIGID Stirling Coolers have a minimum temperature that can be controlled to -160℃, ±0.1℃. Furthermore, the Cryocooler has the smallest footprints, which is very suitable for deep, and fast low-temperature transportation and cold chain logistics.
Key Features
A Game-Changer For Next-Generation Deep Freezing - State Of The Art!
Evaporating Temp Below -99 ℃
Temperature down to -99℃ in few mins. It's suitable for strict temperature control. Depending on the heat mass, cooling capacity and speed can be fine-tuned.
Temperature Below -160 ℃
No OIL, No CFC.
It adopts helium as coolant, MagLev technology. It can reach maximum ultra deep temp -160℃ (only RS100), with 50% energy savings.
Most Compact & Lightweight
RIGID stirling cooler can be installed on various applications, especially for portable equipment because of its compactness and lightweight.
Completed & Integrated
RIGID Stirling cooler, drive board, temperature control and fan are integrated in one unit. You can install it into your system or equipment as it is.
Zero Maintenance & Less Engineering
Integrated configuration, no solder joints, which greatly improves reliability while reducing after-sales maintenance.
Long Continuous Operation
Stirling convertor sets achieves 14-Year continuous operation milestone, record-breaking power convertor.
Refrigerant CFC Free & Oil Free
Freon or other substitutes have been completely eliminated. No need oil operation, no wear, low failure rate.
All-Round Installation Available
Installation angle is not required, can be 360° rotation. Shock resistant, less vibration, ultra low working noise.
APPLICATIONS
RIGID ULT Stirling Cold Solutions Are Trusted in a Variety of Applications.
RIGID Stirling Coolers not only are the most environmentally sustainable ultra-low temperature (ULT) coolers on the market, but they are also the most cost-effective with the lowest life cycle costs. You can benefit from breakthrough Stirling cooler technology without compromising cooling performance across the entire research organization with your devices or equipment.

Military & Aerospace

Medical & Laboratory

Bio-tech Pharma

Semiconductor

Vaccine Transportation

Smart Cold Chain

Portable Freezer

X-Ray Machines
Components & Parts
Premium Technology with the lowest total cost of ownership!